No Image Found   

Check List Report

Deoghar Municipal Corporation

Version Number: 1.0.64  
Version Date: 16/10/2020 
Report Generated On: 14-11-2022 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDEOGHAR
AuthorityDEOGHAR MUNICIPAL CORPORATION
Inward_NoDGMC/BP/0099/W18/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDeoghar
Taluka18
Architect Details
Architect NameUJJAWAL KUMAR
License No.DGMC/ENG/0005/2016
Architect AddressINDU BHUSHAN SARKAR ROAD,WILLIAMS TOWN
Architect EmailIDujjawalkmr862@gmail.com
Architect Mobile No9835573284
Plot Details
Plot Use Commercial
Plot SubUse Other Commercial Building
PlotNearbyReligiousStructure NA
Plot/SubPlot NoT.P.P. NO.- 750
NorthRoad Width - 9.15
SouthPlot No. - LAND OF SRI RAM NARAYAN MISHRA
EastRoad Width - 2.40
WestRoad Width - 3.60
Owner's Details
NameSMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI
AddressNEAR HINDI VIDYAPITH, 24/18, B DEOGHAR
Email IDshastrifci@gmail.com
Mobile No9800832500
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 409.85
2 Plot area as per Document by Applicant 409.85
3 Physical area measured at site 409.70
4 Area as per Site Visit (Site Visit Report) 409.70
5Area as per Drawing 409.70

Area of Plot Considered : 409.70

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Other Commercial Building
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 409.70
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 409.70
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 355.30
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 54.40
54.40
Balance Plot Area 355.30

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 204.85
Proposed Coverage Area ( 49.98 % ) 204.75
Total Prop. Coverage Area ( 49.98 % ) 204.75
Balance coverage area ( 0.02 % ) 0.10
FAR CHECK
Perm. FAR Area ( 2.500 ) 1024.25
Total Perm. FAR area 1024.25
Commercial FAR 962.52
Proposed FAR Area 962.52
Total Proposed FAR Area 962.52
Consumed FAR (Factor) 2.35
Balance FAR Area 61.73
BUA CHECK
Total Proposed BuiltUp Area 1082.07


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 9.15 9.15
Proposed Road Width as per Master Plan 9.15 -
Road Widening Width 0 -
Plot size (as per measurement) 409.7 409.70
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 409.70 OK
Plot Width Mt. - - 9.60 OK
Plot Depth Mt. - - 42.67 OK
Access Width Mt. 6.10 - 9.15 OK
Plot Frontage Mt. - - 9.60 OK
Coverage Area Sq.Mt. - 204.85 204.75 OK
FAR Area Sq.Mt. - 1024.25 962.52 OK
Consumed FAR Sq.Mt. - 2.50 2.35 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 20.49 54.40 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 16.92 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 2.22 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Cover (Plantation) - Minimum Area Sq.Mt. - 37.48 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.48 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 5 OK
Car In Area Sq.Mt. - - 50.00 OK
Two Stack.Car In Area Sq.Mt. - - 37.50 OK
Total Car In Area Sq.Mt. 75.00 - 87.50 OK
TwoWheeler In Area Sq.Mt. - - 24.00 OK
Two Stack. TwoWheeler In Area Sq.Mt. - - 20.00 OK
Total TwoWheeler In Area Sq.Mt. 38.00 - 44.00 OK
DriveWay PLOT - - - 4.60M WIDE DRIVEWAY - Width No. 3.60 - 4.60 OK
A-1 (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI) Front Margin... 9.15 mt. Wide MainRoad Mt. 7.50 - 12.90 OK
Rear Margin Mt. 4.50 - 4.50 OK
Side1 Margin Mt. 1.50 - 1.50 OK
Side2 Margin Mt. - - 0.00 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI) Height Mt. 23.10 15.15 OK
A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI) Fourth Floor - Height Mt. 2.75 - 3.00 OK
Fourth Floor - Clear Height Mt. 2.75 - 2.88 OK
Fourth Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
Third Floor - Height Mt. 2.75 - 3.00 OK
Third Floor - Clear Height Mt. 2.75 - 2.88 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
Second Floor - Height Mt. 2.75 - 3.00 OK
Second Floor - Clear Height Mt. 2.75 - 2.88 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.88 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
Ground Floor - Height Mt. 2.75 - 3.15 OK
Ground Floor - Clear Height Mt. 2.75 - 3.03 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.70 OK
Plinth - Height Mt. 0.45 - 0.90 OK
Plinth - Clear Height Mt. - - 0.90 OK
Plinth - Beam Clear Height Mt. - - 0.90 OK
A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI) Terrace Floor - Height Mt. - - 1.00 OK
Terrace Floor - Clear Height Mt. - - 1.00 OK
Terrace Floor - Beam Clear Height Mt. - - 1.00 OK
A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI) No. of Floors No. G + 6 5 OK
No. of Tenements No. - 5 OK
A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI) FIRST FLOOR PLAN - BALCONY - Width Mt. 1.20 0.90 OK
TYPICAL - 2, 3& 4 FLOOR PLAN - BALCONY - Width Mt. 1.20 1.20 OK
TYPICAL - 2, 3& 4 FLOOR PLAN - BALCONY - Width Mt. 0.90 0.90 OK
A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI) Number Of Lift(s) No. 2 2 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. 12 12 OK
A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI) GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 1.92 OK
FIRST FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
FIRST FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
FIRST FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
FIRST FLOOR PLAN - Lift - Depth Mt. 1.90 1.92 OK
TYPICAL - 2, 3& 4 FLOOR PLAN - Lift Lobby - Width Mt. 1.70 1.80 OK
TYPICAL - 2, 3& 4 FLOOR PLAN - Lift Lobby - Depth Mt. 1.90 3.69 OK
TYPICAL - 2, 3& 4 FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
TYPICAL - 2, 3& 4 FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
TYPICAL - 2, 3& 4 FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
TYPICAL - 2, 3& 4 FLOOR PLAN - Lift - Depth Mt. 1.90 1.92 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.93 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.36 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 2.16 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.38 OK
GROUND FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 1.198 OK
Staircase -3FL - Tread Width Mt. 0.250 0.250 OK
Staircase -3FL - Riser Height Mt. 0.200 0.088 OK
Staircase -3FL - Riser No. On Flight No. - 10 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
Staircase -3FL - Flight Width Mt. 0.900 1.200 OK
Staircase -3FL - Tread Width Mt. 0.250 0.250 OK
Staircase -3FL - Riser Height Mt. 0.200 0.088 OK
Staircase -3FL - Riser No. On Flight No. - 12 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 1.198 OK
Staircase -3FL - Tread Width Mt. 0.250 0.250 OK
Staircase -3FL - Riser Height Mt. 0.200 0.083 OK
Staircase -3FL - Riser No. On Flight No. - 10 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
Staircase -3FL - Flight Width Mt. 0.900 1.200 OK
Staircase -3FL - Tread Width Mt. 0.250 0.250 OK
Staircase -3FL - Riser Height Mt. 0.200 0.083 OK
Staircase -3FL - Riser No. On Flight No. - 12 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
TYPICAL - 2, 3& 4 FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 1.198 OK
Staircase -3FL - Tread Width Mt. 0.250 0.250 OK
Staircase -3FL - Riser Height Mt. 0.200 0.083 OK
Staircase -3FL - Riser No. On Flight No. - 10 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN Staircase -3FL - Flight Width Mt. - 1.198 OK
Staircase -3FL - Tread Width Mt. - 0.250 OK
Staircase -3FL - Riser Height Mt. - - OK
Staircase -3FL - Riser No. On Flight No. - - OK
Staircase -3FL - Cabin Ht. Mt. - - 2.525 OK
Toilet Area Sq.Mt. - 5.00 1.44 OK
Width Mt. - - 1.20 OK
Depth Mt. - - 1.20 OK
Height Mt. - - - OK
SEPTIC TANK Area Sq.Mt. - - 1.09 OK
Width Mt. - - 0.69 OK
Depth Mt. - - 1.58 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.09 OK
Width Mt. - - 0.69 OK
Depth Mt. - - 1.58 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.58 OK
Width Mt. - - 0.13 OK
Depth Mt. - - 4.60 OK
Height Mt. - - - OK
GUARD ROOM Area Sq.Mt. - 10.00 3.72 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 2.07 OK
Height Mt. - - - OK
Entrance Lobby Area Sq.Mt. - 12.00 6.49 OK
Width Mt. - - 1.93 OK
Depth Mt. - - 3.36 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 8.51 OK
Width Mt. - - 1.65 OK
Depth Mt. - - 5.15 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 6.49 OK
Width Mt. - - 1.93 OK
Depth Mt. - - 3.36 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 8.51 OK
Width Mt. - - 1.65 OK
Depth Mt. - - 5.15 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 8.59 OK
Width Mt. - - 2.50 OK
Depth Mt. - - 3.69 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.09 OK
Width Mt. - - 0.69 OK
Depth Mt. - - 1.58 OK
Height Mt. - - - OK
A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) ; In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
(3) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(4) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 39-45 mt. and Plot width upto 10 mt., Margin required in Front shall be 7.5 mt., Rear 4.5 mt. and Atleast 1.5 mt. shall be provided at one side. {As per Rule No. 36 Table 10 & 11}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony (1) Projected balcony may be allowed with a widt of 1.2 mt. where the setback is more than 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Projected balcony may be allowed with a widt of 0.9 mt. where the setback is between 2.0 mt. to 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) Lift lobby should be not free from FAR
(6) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(7) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SEPTIC TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
(8) Guard room of max. 10 sq.mt. maximum size of 5 sq.mt shall be taken Free from FAR
(9) No need to check distance from Building GUARD ROOM
(10) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(11) No need to check distance from Building Entrance Lobby
(12) -
(13) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)