No Image Found   

Detail Scrutiny Report

Deoghar Municipal Corporation

Version Number: 1.0.64  
Version Date: 16/10/2020 
Report Generated On: 14-11-2022 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDEOGHAR
AuthorityDEOGHAR MUNICIPAL CORPORATION
Inward_NoDGMC/BP/0099/W18/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDeoghar
Taluka18
Architect Details
Architect NameUJJAWAL KUMAR
License No.DGMC/ENG/0005/2016
Architect AddressINDU BHUSHAN SARKAR ROAD,WILLIAMS TOWN
Architect EmailIDujjawalkmr862@gmail.com
Architect Mobile No9835573284
Plot Details
Plot Use Commercial
Plot SubUse Other Commercial Building
PlotNearbyReligiousStructure NA
Plot/SubPlot NoT.P.P. NO.- 750
NorthRoad Width - 9.15
SouthPlot No. - LAND OF SRI RAM NARAYAN MISHRA
EastRoad Width - 2.40
WestRoad Width - 3.60
Owner's Details
NameSMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI
AddressNEAR HINDI VIDYAPITH, 24/18, B DEOGHAR
Email IDshastrifci@gmail.com
Mobile No9800832500
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 409.85
2 Plot area as per Document by Applicant 409.85
3 Physical area measured at site 409.70
4 Area as per Site Visit (Site Visit Report) 409.70
5Area as per Drawing 409.70

Area of Plot Considered : 409.70

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Other Commercial Building
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 409.70
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 409.70
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 355.30
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 54.40
54.40
Balance Plot Area 355.30

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 204.85
Proposed Coverage Area ( 49.98 % ) 204.75
Total Prop. Coverage Area ( 49.98 % ) 204.75
Balance coverage area ( 0.02 % ) 0.10
FAR CHECK
Perm. FAR Area ( 2.500 ) 1024.25
Total Perm. FAR area 1024.25
Commercial FAR 962.52
Proposed FAR Area 962.52
Total Proposed FAR Area 962.52
Consumed FAR (Factor) 2.35
Balance FAR Area 61.73
BUA CHECK
Total Proposed BuiltUp Area 1082.07


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 9.15 9.15
Proposed Road Width as per Master Plan 9.15 -
Road Widening Width 0 -
Plot size (as per measurement) 409.7 409.70
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 20.49 54.40 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 16.92 0.00 0.00 - 2.22 - 90.00 2.40 mt. Wide MainRoad Access Road OK
Tree Cover (Plantation) - 37.48 0.00 0.00 - 1.48 - 90.00 2.40 mt. Wide MainRoad Access Road OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 5 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI) Commercial Other Commercial Building Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI) 23.10 15.15 15.15 15.15 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI) Fourth Floor 2.75 - 3.00 2.75 - 2.88 2.40 - 2.55 OK
Third Floor 2.75 - 3.00 2.75 - 2.88 2.40 - 2.55 OK
Second Floor 2.75 - 3.00 2.75 - 2.88 2.40 - 2.55 OK
First Floor 2.75 - 3.00 2.75 - 2.88 2.40 - 2.55 OK
Ground Floor 2.75 - 3.15 2.75 - 3.03 2.40 - 2.70 OK
Plinth 0.45 - 0.90 - - 0.90 - - 0.90 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI) Terrace Floor - - 1.00 - - 1.00 - - 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI) G + 6 5 - 5 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
204.85 204.75 OK
50% 49.98%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI) - 204.75
  Total Prop. Coverage Area - 204.75
  Total Coverage Area 204.85 204.75

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Balcony Void Accessory Use Commercial
A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI) 1 1082.07 25.96 19.90 17.93 55.77 962.52 962.51 962.51 05
Grand Total : 1 1082.07 25.96 19.90 17.93 55.77 962.52 962.51 962.51 05


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 204.75 189.75 204.75 189.75
First Floor 212.04 170.60 212.04 170.60
Second Floor 221.76 200.72 221.76 200.72
Third Floor 221.76 200.72 221.76 200.72
Fourth Floor 221.76 200.72 221.76 200.72
Terrace Floor 0.00 0.00 0.00 0.00
Total : 1082.07 962.51 1082.07 962.51


[-] UnitBUA Table for Building :A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN HALL OTHER 152.43 152.09 4 1
FIRST FLOOR PLAN HALL OTHER 137.78 137.44 3 1
TYPICAL - 2, 3& 4 FLOOR PLAN LODGE OTHER 163.97 163.63 5 3
Total: - - 782.12 780.43 22 5


[-] Building :A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Balcony Void Accessory Use Commercial
Ground Floor 204.75 0.00 0.00 0.00 15.00 189.75 189.75 189.75 01
First Floor 212.04 6.49 2.02 17.93 15.00 170.60 170.60 170.60 01
Second Floor 221.76 6.49 5.96 0.00 8.59 200.72 200.72 200.72 01
Third Floor 221.76 6.49 5.96 0.00 8.59 200.72 200.72 200.72 01
Fourth Floor 221.76 6.49 5.96 0.00 8.59 200.72 200.72 200.72 01
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 1082.07 25.96 19.90 17.93 55.77 962.52 962.51 962.51 05
Total Number of Same Buildings : 1
Total : 1082.07 25.96 19.90 17.93 55.77 962.52 962.51 962.51 05
[-] Table 4c-2

  FAR Area
Building FAR Area:962.52
Existing FAR Area :0.00
Perm.
1024.25
Prop.
962.52
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI) 9.15 mt. Wide MainRoad 7.50 12.90 4.50 4.50 1.50 1.50 - 0.00 OK






[-] Inner Building Details (Table 6)
   
   
[-] Balcony Details (Table 6c)

[-] For Building:A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI)
Floor Name Balcony Name Width Status
Perm Prop
FIRST FLOOR PLAN BALCONY 1.20 0.90 OK
TYPICAL - 2, 3& 4 FLOOR PLAN BALCONY 1.20 1.20 OK
BALCONY 0.90 0.90 OK



For PWork At Layout : 

No Balcony Found.

   
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI) 15.15 2 2 - 0 12 12 OK

[-] Lift Check Table

[-] For Building :A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
GROUND FLOOR PLAN Lift 1.70 1.70 1.90 1.90 OK
Lift 1.70 1.70 1.90 1.92 OK
FIRST FLOOR PLAN Lift 1.70 1.70 1.90 1.90 OK
Lift 1.70 1.70 1.90 1.92 OK
TYPICAL - 2, 3& 4 FLOOR PLAN Lift Lobby 1.70 1.80 1.90 3.69 OK
Lift 1.70 1.70 1.90 1.90 OK
Lift 1.70 1.70 1.90 1.92 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.93 1.90 2.36 OK
Lift Machine Room 1.70 2.16 1.90 2.38 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI) Commercial Other Commercial Building > 0 100 292.69 1 2 - - - -
> 0 100 292.69 - - - 1 7 -
Lodging > 0 100 530.60 1 4 - - - -
> 0 100 530.60 - - - 1 12 -
Total : - - - - 6 7 - 19 12

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 4 50.00 OK
Two Stack.Car - - 3 37.50 OK
Total Car 6 75.00 7 87.50 OK
TwoWheeler - - 12 24.00 OK
Two Stack. TwoWheeler - - 10 20.00 OK
Total TwoWheeler 19 38.00 22 44.00 OK
Total 113.00 175.50 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
PLOT - 4.60M WIDE DRIVEWAY 3.60 - 4.60 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN Staircase -3FL 0.900 1.198 0.250 0.250 0.200 0.088 - 10 - - 0.000 OK
Staircase -3FL 0.900 1.200 0.250 0.250 0.200 0.088 - 12 - - 0.000 OK
FIRST FLOOR PLAN Staircase -3FL 0.900 1.198 0.250 0.250 0.200 0.083 - 10 - - 0.000 OK
Staircase -3FL 0.900 1.200 0.250 0.250 0.200 0.083 - 12 - - 0.000 OK
TYPICAL - 2, 3& 4 FLOOR PLAN Staircase -3FL 0.900 1.198 0.250 0.250 0.200 0.083 - 10 - - 0.000 OK
TERRACE FLOOR PLAN Staircase -3FL - 1.198 - 0.250 - 0.000 - 0 - - 2.525 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 1.44 - - 1.20 - - 1.20 - - 0.00 OK
SEPTIC TANK - - 1.09 - - 0.69 - - 1.58 - - 0.00 OK
RAIN WATER HARVESTING - - 1.09 - - 0.69 - - 1.58 - - 0.00 OK
ENT.GATE - - 0.58 - - 0.13 - - 4.60 - - 0.00 OK
GUARD ROOM - 10.00 3.72 - - 1.80 - - 2.07 - - 0.00 OK
Entrance Lobby - 12.00 6.49 - - 1.93 - - 3.36 - - 0.00 OK
Entrance Lobby - 12.00 8.51 - - 1.65 - - 5.15 - - 0.00 OK
Entrance Lobby - 12.00 6.49 - - 1.93 - - 3.36 - - 0.00 OK
Entrance Lobby - 12.00 8.51 - - 1.65 - - 5.15 - - 0.00 OK
Entrance Lobby - 12.00 8.59 - - 2.50 - - 3.69 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.09 - - 0.69 - - 1.58 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (SMT GEETANJALI SHASTRI AND SRI KAMLA KANT SHASTRI)


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:FIRST FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:TYPICAL - 2, 3& 4 FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 409.70 OK
  Plot Width - 9.60 OK
  Plot Depth - 42.67 OK
  Access Width 6.10 9.15 OK
  Plot Frontage - 9.60 OK
  Coverage Area 204.85 204.75 OK
  FAR Area
Bldg. FAR Area : 962.52
Sanctioned FAR Area :0.00
1024.25 962.52 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) ; In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
(3) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(4) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 39-45 mt. and Plot width upto 10 mt., Margin required in Front shall be 7.5 mt., Rear 4.5 mt. and Atleast 1.5 mt. shall be provided at one side. {As per Rule No. 36 Table 10 & 11}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony (1) Projected balcony may be allowed with a widt of 1.2 mt. where the setback is more than 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Projected balcony may be allowed with a widt of 0.9 mt. where the setback is between 2.0 mt. to 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) Lift lobby should be not free from FAR
(6) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(7) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SEPTIC TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
(8) Guard room of max. 10 sq.mt. maximum size of 5 sq.mt shall be taken Free from FAR
(9) No need to check distance from Building GUARD ROOM
(10) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(11) No need to check distance from Building Entrance Lobby
(12) -
(13) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)