No Image Found   

Failed List Report

Deoghar Municipal Corporation

Version Number: 1.0.70  
Version Date: 16/10/2020 
Report Generated On: 27-06-2024 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDEOGHAR
AuthorityDEOGHAR MUNICIPAL CORPORATION
Inward_NoDGMC/BP/0053/W32/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDeoghar
Taluka18
Architect Details
Architect NameNIRAJ KUMAR
License No.DGMC/ARC/0007/2020
Architect AddressAT + POST - PARARI , SAHARSA
Architect EmailIDar.nirajk@gmail.com
Architect Mobile No9939963509
Plot Details
Plot Use Commercial
Plot SubUse Shop
PlotNearbyReligiousStructure NA
Plot/SubPlot NoTPP748
NorthPlot No. - Land of Kishor JhunJhunwala
SouthRoad Width - 40
EastPlot No. - Land of Saler
WestRoad Width - 50
Owner's Details
NameRajesh Kumar And Babita Devi
AddressCaster Town , Station Road, Deoghar, Jharkhand
Email IDrajeshmandal3277@gmail.com
Mobile No9204004729
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 132.01
2 Plot area as per Document by Applicant 132.18
3 Physical area measured at site 132.00
4 Area as per Site Visit (Site Visit Report) 132.00
5Area as per Drawing 132.18

Area of Plot Considered : 132.00

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Shop
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 132.00
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 132.00
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 118.17
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 13.83
13.83
Balance Plot Area 118.17

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 66.00
Proposed Coverage Area ( 42.21 % ) 55.72
Total Prop. Coverage Area ( 42.21 % ) 55.72
Balance coverage area ( 7.79 % ) 10.28
FAR CHECK
Perm. FAR Area ( 2.500 ) 330.00
Total Perm. FAR area 330.00
Commercial FAR 278.58
Proposed FAR Area 278.58
Total Proposed FAR Area 278.58
Consumed FAR (Factor) 2.11
Balance FAR Area 51.42
BUA CHECK
Total Proposed BuiltUp Area 278.60


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 15.24 15.24
Proposed Road Width as per Master Plan 15.24 -
Road Widening Width 0 -
Plot size (as per measurement) 132 132.18
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK
   



[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Deoghar Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 10-15 mt. and Plot width upto 10 mt., Margin required in Front shall be 4.5 mt., Rear 2.0 mt. and Atleast 1.5 mt. shall be provided at one side. {As per Rule No. 36 Table 10 & 11 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 }
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)