General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDHANBAD
AuthorityMINERAL AREA DEVELOMENT AUTHORITY
Inward_NoMADA/BP/0349/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageJialgora
Taluka15
Architect Details
Architect NameRAM PRATAP SINGH
License No.MADA/ARC/0024/2019
Architect AddressKAUSHALYA KUTIR SRIRAMKUNJ COLONY NAWADIH HIRAK ROAD
Architect EmailIDar.rampratap@GMAIL.COM
Architect Mobile No9525550001
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot NoOLD PLOT NO. 502, NEW PLOT NO. 1446
NorthPlot No. - SAME PLOT
SouthPlot No. - SAME PLOT
EastRoad Width - 6.10
WestPlot No. - SAME PLOT
Owner's Details
NameSMT. JYOTI KUMARI
AddressHOUSE NO. WB/94 GAYATRI COLONY, PO. KATHARA, PS. BOKARO, DIST. BOKARO JHARKHAND
Email IDsujeetsinhahp@gmail.com
Mobile No9816402802
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 104.04
2 Plot area as per Document by Applicant 104.04
3 Physical area measured at site 103.82
4 Area as per Site Visit (Site Visit Report) 103.82
5Area as per Drawing 103.82

Area of Plot Considered : 103.82

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 103.82
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 103.82
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 93.44
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 10.38
10.38
Balance Plot Area 93.44

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 72.67
Proposed Coverage Area ( 56.61 % ) 58.77
Total Prop. Coverage Area ( 56.61 % ) 58.77
Balance coverage area ( 13.39 % ) 13.90
FAR CHECK
Perm. FAR Area ( 2.50 ) 259.55
Total Perm. FAR area 259.55
Residential FAR 117.55
Proposed FAR Area 117.55
Total Proposed FAR Area 117.55
Consumed FAR (Factor) 1.13
Balance FAR Area 142.00
BUA CHECK
Total Proposed BuiltUp Area 118.41


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 6.1 -
Road Widening Width 0 -
Plot size (as per measurement) 103.82 103.82
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 5.19 10.38 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Access Status
Reqd Prop
Normal Open Space - 10.38 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 3 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
JYOTI (KUMARI) Residential Residential Bldg/Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
JYOTI (KUMARI) 11.16 6.59 6.59 6.59 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
JYOTI (KUMARI) First Floor 2.75 - 3.30 2.75 - 3.20 2.40 - 3.05 OK
Ground Floor 2.75 - 3.29 2.75 - 3.19 2.40 - 3.04 OK
Plinth 0.45 - 0.61 - - 0.61 - - 0.61 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
JYOTI (KUMARI) Terrace Floor - - 1.01 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
JYOTI (KUMARI) G + 4 2 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
72.67 58.77 OK
70% 56.61%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  JYOTI-1 (KUMARI) - 58.77
  Total Prop. Coverage Area - 58.77
  Total Coverage Area 72.67 58.77

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
StairCase Resi.
JYOTI (KUMARI) 1 118.41 0.87 117.54 117.54 117.54 01
Grand Total : 1 118.41 0.87 117.54 117.54 117.54 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
JYOTI (KUMARI)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 59.64 58.77 59.64 58.77
First Floor 58.77 58.77 58.77 58.77
Terrace Floor 0.00 0.00 0.00 0.00
Total : 118.41 117.54 118.41 117.54


[-] UnitBUA Table for Building :JYOTI (KUMARI)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT 1 FLAT 117.55 117.46 5 1
FIRST FLOOR PLAN SPLIT 1 FLAT 0.00 0.00 6 0
Total: - - 117.55 117.46 11 1


[-] Building :JYOTI (KUMARI)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
StairCase Resi.
Ground Floor 59.64 0.87 58.77 58.77 58.77 01
First Floor 58.77 0.00 58.77 58.77 58.77 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 00
Total : 118.41 0.87 117.54 117.54 117.54 01
Total Number of Same Buildings : 1
Total : 118.41 0.87 117.54 117.54 117.54 01
[-] Table 4c-2

  FAR Area
Building FAR Area:117.55
Existing FAR Area :0.00
Perm.
259.55
Prop.
117.55
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
JYOTI-1 (KUMARI) 6.10 mt. Wide MainRoad 2.00 2.01 1.50 1.50 0.90 0.91 - 0.90 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Residential Bldg/Apartment, In Building: JYOTI (KUMARI)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :JYOTI (KUMARI)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.750 0.891 0.225 0.254 0.200 0.150 - 11 - - 0.000 OK
OPEN STAIRCASE - 1.434 - 0.203 - 1.645 - 2 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.750 0.891 0.225 0.254 0.200 0.165 - 10 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 0.891 - 0.254 - 0.000 - 0 2.100 - 2.438 OK

In JYOTI (KUMARI) Bldg in GROUND FLOOR PLAN ,

In JYOTI (KUMARI) Bldg in GROUND FLOOR PLAN , OPEN STAIRCASE shall not be allowed in Front marginal open space.

In JYOTI (KUMARI) Bldg in GROUND FLOOR PLAN , OPEN STAIRCASE shall not be permitted in less than 3.mt. marginal open space

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 2.08 - - 0.95 - - 2.19 - - 0.00 OK
RAIN WATER HARVESTING - - 1.97 - - 1.33 - - 1.49 - - 0.00 OK
SOLAR HEATING SYSTEM - - 4.31 - - 1.41 - - 3.05 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
JYOTI (KUMARI) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:JYOTI (KUMARI)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 103.82 OK
  Plot Width - 7.92 OK
  Plot Depth - 13.10 OK
  Access Width - 6.10 OK
  Plot Frontage - 7.92 OK
  Coverage Area 72.67 58.77 OK
  FAR Area
Bldg. FAR Area : 117.55
Sanctioned FAR Area :0.00
259.55 117.55 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For this Authority, No Max. permissible FAR has been provided {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For this Authority, No Max. permissible FAR has been provided {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot ; ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
(5) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(6) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)