No Image Found   

Failed List Report

Mineral Area Development Authority

Version Number: 1.0.62  
Version Date: 16/10/2020 
Report Generated On: 26-02-2022 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDHANBAD
AuthorityMINERAL AREA DEVELOMENT AUTHORITY
Inward_NoMADA/BP/0336/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageKangalo
Taluka15
Architect Details
Architect NameKUSHJEE PANDEY
License No.MADA/ARC/0027/2019
Architect Address503 aaditya apartment saraidhela
Architect EmailIDkush@abhikalpadesign.com
Architect Mobile No9643660451
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot NoOLD – 269 , NEW - 327
NorthPlot No. - PORTION OF THIS PLOT
SouthPlot No. - PORTION OF THIS PLOT
EastPlot No. - OLD PLOT NO. - 268 PART
WestRoad Width - 3.65
Owner's Details
NameLAXMI DEVI
AddressKANKANI LOYABAD , PS - LOYABAD , DHANBAD
Email IDroushansahanii@gmail.com
Mobile No8292649805
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 212.94
2 Plot area as per Document by Applicant 212.94
3 Physical area measured at site 209.69
4 Area as per Site Visit (Site Visit Report) 209.69
5Area as per Drawing 209.69

Area of Plot Considered : 209.69

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 209.69
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 209.69
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 176.11
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 33.58
33.58
Balance Plot Area 176.11

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 146.78
Proposed Coverage Area ( 59.25 % ) 124.25
Total Prop. Coverage Area ( 59.25 % ) 124.25
Balance coverage area ( 10.74 % ) 22.53
FAR CHECK
Perm. FAR Area ( 1.20 ) 251.63
Total Perm. FAR area 251.63
Residential FAR 248.50
Proposed FAR Area 248.50
Total Proposed FAR Area 248.50
Consumed FAR (Factor) 1.19
Balance FAR Area 3.13
BUA CHECK
Total Proposed BuiltUp Area 248.50


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 3.13 3.13
Proposed Road Width as per Master Plan 3.13 -
Road Widening Width 0 -
Plot size (as per measurement) 209.69 209.69
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
A-1 (BUILDING) ResvRoad Width Check for... 3.13 METER WIDE ROAD Mt. 0.23 0.00 Failed

       



[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For this Authority, No Max. permissible FAR has been provided {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For this Authority, No Max. permissible FAR has been provided {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 21-27 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road upto 50 mt. shall be 3.6 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road upto 50 mt. shall be 3.6 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area location, on Road width upto 3.6 mt.,Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 7.0 mt. {As per Rule No. 39.1 Note 1}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width upto 3.6 mt. only G+1 floors shall be allowed {As per Rule No. 39.1 Note 1}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)