No Image Found   

Failed List Report

Mineral Area Development Authority

Version Number: 1.0.62  
Version Date: 16/10/2020 
Report Generated On: 16-06-2022 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDHANBAD
AuthorityMINERAL AREA DEVELOMENT AUTHORITY
Inward_NoMADA/BP/0095/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageJialgora
Taluka15
Architect Details
Architect NameKumud kanchan
License No.MADA/ARC/0010/2019
Architect Address15A CMWO Cooperative Colony Koyla Nagar
Architect EmailIDkumudkanchan28@gmail.com
Architect Mobile No7633999700
Plot Details
Plot Use Commercial
Plot SubUse Hotel
PlotNearbyReligiousStructure NA
Plot/SubPlot NoOLD-422, 423,424, 425, 427, 446, 447, 448, 449,1345 NEW - 502, 535, 536, 537, 539, 540, 541, 542,543
NorthRoad Width - 30.00
SouthPlot No. - VENDOR OWN LAND
EastPlot No. - 503,504,510,531,532,535
WestPlot No. - INTERNAL ROAD
Owner's Details
NameSRI GOURAV SARKAR
AddressBESIDE SAMBODHI RETREAT VAASTU VIHAR, NH-2 GOBINDPUR, DHANBAD
Email IDtauquirnishat@gmail.com
Mobile No8655495686
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 3926.51
2 Plot area as per Document by Applicant 3926.51
3 Physical area measured at site 3925.50
4 Area as per Site Visit (Site Visit Report) 3925.50
5Area as per Drawing 3925.49

Area of Plot Considered : 3925.49

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Hotel
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 3925.49
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 3925.49
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 3430.76
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 494.72
494.72
Balance Plot Area 3430.76

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 1962.74
Proposed Coverage Area ( 12.67 % ) 497.27
Total Prop. Coverage Area ( 12.67 % ) 497.27
Balance coverage area ( 37.33 % ) 1465.47
FAR CHECK
Perm. FAR Area ( 3.00 ) 11776.47
Total Perm. FAR area 11776.47
Commercial FAR 2427.18
Proposed FAR Area 2427.18
Total Proposed FAR Area 2427.18
Consumed FAR (Factor) 0.62
Balance FAR Area 9349.29
BUA CHECK
Total Proposed BuiltUp Area 2453.31


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 30 30.00
Proposed Road Width as per Master Plan 30 -
Road Widening Width 0 -
Plot size (as per measurement) 3925.5 3925.49
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK
   



[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for Hotel (below three star) category shall be 1000.0 sq.mt.{As per Rule No. 35.1, Table 7}
Plot Width The minimum size of plot for Hotel (below three star) category shall be 1000.0 sq.mt.{As per Rule No. 35.1, Table 7}
Plot Depth The minimum size of plot for Hotel (below three star) category shall be 1000.0 sq.mt.{As per Rule No. 35.1, Table 7}
Access Width The minimum width of abutting road for Hotel (below three star) category shall be 12.20 mt.{As per Rule No. 35.1, Table 7}
Plot Frontage The minimum size of plot for Hotel (below three star) category shall be 1000.0 sq.mt.{As per Rule No. 35.1, Table 7}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For this Authority, No Max. permissible FAR has been provided {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For this Authority, No Max. permissible FAR has been provided {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule (1) For Plor area above 2000 sq.mt., The minimum width or driveways should not be less than 4.50 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
Margin Rule For Commercial & Storage buildings having plotarea above 1000 sq.mt., Margin required in Front shall be 9.0 mt., Rear 6.0 mt. and 6.0 mt. shall be provided on both side. {As per Rule No. 38.2.5}
Building Level
Building Height For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) Lift lobby should be not free from FAR
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) The area of lift well shall not be counted for F.A.R calculation)
(6) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(7) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Hotels, Lodges And Guest Houses type of Building, Provisions of Solar Water Heating System shall be done. Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)