-
No Image Found   

Check List Report

Mineral Area Development Authority

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 13-10-2023 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDHANBAD
AuthorityMINERAL AREA DEVELOMENT AUTHORITY
Inward_NoMADA/BP/0304/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageNichitpur
Taluka15
Architect Details
Architect NameLalan Prasad Singh
License No.MADA/ENG/0001/2020
Architect AddressEr. L P Singh, In Front of Binod Bihari Mahato, Chiragora, Dhanbad, Jharkhand
Architect EmailIDlalanprasadsingh.jh@gmail.com
Architect Mobile No8409877028
Plot Details
Plot Use Commercial
Plot SubUse Commercial Bldg
PlotNearbyReligiousStructure NA
Plot/SubPlot NoOLD - 485, 489, NEW- 683
NorthPlot No. - PART OF THIS PLOT
SouthRoad Width - 6.1
EastPlot No. - PART OF SAME PLOT
WestPlot No. - NEW PLOT NO. 684
Owner's Details
NameHARIPAD GOPE
AddressNICHITPUR, BALIYAPUR, DHANBAD
Email IDhaldhardawndhn@gmail.com
Mobile No9835662356
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 17824.78
2 Plot area as per Document by Applicant 3392.68
3 Physical area measured at site 3392.68
4 Area as per Site Visit (Site Visit Report) 3392.68
5Area as per Drawing 3392.68

Area of Plot Considered : 3392.68

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
Plotplot
Plot OccupancyCommercial
Plot SubUse Commercial Bldg
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 3392.68
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 3392.68
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 3107.72
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 284.96
284.96
Balance Plot Area 3107.72

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 1696.34
Proposed Coverage Area ( 26.30 % ) 892.29
Total Prop. Coverage Area ( 26.3 % ) 892.29
Balance coverage area ( 23.70 % ) 804.05
FAR CHECK
Perm. FAR Area ( 2.500 ) 8481.70
Total Perm. FAR area 8481.70
Commercial FAR 3400.49
Proposed FAR Area 3400.49
Total Proposed FAR Area 3400.49
Consumed FAR (Factor) 1.00
Balance FAR Area 5081.21
BUA CHECK
Total Proposed BuiltUp Area 3420.48


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 6.1 -
Road Widening Width 0 -
Plot size (as per measurement) 3392.68 3392.68
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 3392.68 OK
Plot Width Mt. - - 49.67 OK
Plot Depth Mt. - - 68.30 OK
Access Width Mt. - - 6.10 OK
Plot Frontage Mt. - - 49.38 OK
Coverage Area Sq.Mt. - 1696.34 892.29 OK
FAR Area Sq.Mt. - 8481.70 3400.49 OK
Consumed FAR Sq.Mt. - 2.50 1.00 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 169.63 284.96 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 284.96 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 8.22 OK
Tree Cover (Plantation) - Angle Degree - 81.61 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 8 11 OK
Car In Area Sq.Mt. - - 200.00 OK
Total Car In Area Sq.Mt. 150.00 - 200.00 OK
TwoWheeler In Area Sq.Mt. - - 76.00 OK
Total TwoWheeler In Area Sq.Mt. 70.00 - 76.00 OK
DriveWay plot - - - driveway - Width No. 4.50 - 10.00 OK
B -1 (B ) Front Margin... 6.1m wide road Mt. 9.00 - 9.15 OK
Rear Margin Mt. 6.00 - 47.72 OK
Side1 Margin Mt. 6.00 - 6.57 OK
Side2 Margin Mt. 6.00 - 30.61 OK
A-1 (A) Front Margin... 6.1m wide road Mt. 9.00 - 36.15 OK
Rear Margin Mt. 6.00 - 6.19 OK
Side1 Margin Mt. 6.00 - 6.57 OK
Side2 Margin Mt. 6.00 - 12.32 OK
B -1 (B ) A-1 (A) - Margin Mt. 9.00 14.81 OK
A-1 (A) B -1 (B ) - Margin Mt. 9.00 14.81 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
B (B ) Height Mt. 16.40 9.60 OK
A (A) Height Mt. 16.40 12.80 OK
B (B ) Second Floor - Height Mt. 2.75 - 3.20 OK
Second Floor - Clear Height Mt. 2.75 - 3.10 OK
Second Floor - Beam Clear Height Mt. 2.40 - 3.10 OK
First Floor - Height Mt. 2.75 - 3.20 OK
First Floor - Clear Height Mt. 2.75 - 3.10 OK
First Floor - Beam Clear Height Mt. 2.40 - 3.10 OK
Ground Floor - Height Mt. 2.75 - 3.20 OK
Ground Floor - Clear Height Mt. 2.75 - 3.10 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 3.10 OK
A (A) Third Floor - Height Mt. 2.75 - 3.20 OK
Third Floor - Clear Height Mt. 2.75 - 3.10 OK
Third Floor - Beam Clear Height Mt. 2.40 - 3.10 OK
Second Floor - Height Mt. 2.75 - 3.20 OK
Second Floor - Clear Height Mt. 2.75 - 3.10 OK
Second Floor - Beam Clear Height Mt. 2.40 - 3.10 OK
First Floor - Height Mt. 2.75 - 3.20 OK
First Floor - Clear Height Mt. 2.75 - 3.10 OK
First Floor - Beam Clear Height Mt. 2.40 - 3.10 OK
Ground Floor - Height Mt. 2.75 - 3.20 OK
Ground Floor - Clear Height Mt. 2.75 - 3.10 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 3.10 OK
B (B ) Terrace Floor - Height Mt. - - 1.07 OK
Terrace Floor - Clear Height Mt. - - 1.07 OK
Terrace Floor - Beam Clear Height Mt. - - 1.07 OK
A (A) Terrace Floor - Height Mt. - - 1.07 OK
Terrace Floor - Clear Height Mt. - - 1.07 OK
Terrace Floor - Beam Clear Height Mt. - - 1.07 OK
B (B ) No. of Floors No. G + 4 3 OK
No. of Tenements No. - 3 OK
A (A) No. of Floors No. G + 4 4 OK
No. of Tenements No. - 4 OK
A (A) Number Of Lift(s) No. 2 2 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. 12 12 OK
B (B ) Number Of Lift(s) No. - 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. - 6 OK
A (A) TYPICAL - 1, 2, 3 FLOOR PLAN - Lift - Width Mt. 1.70 2.14 OK
TYPICAL - 1, 2, 3 FLOOR PLAN - Lift - Depth Mt. 1.90 2.34 OK
TYPICAL - 1, 2, 3 FLOOR PLAN - Lift - Width Mt. 1.70 2.14 OK
TYPICAL - 1, 2, 3 FLOOR PLAN - Lift - Depth Mt. 1.90 2.34 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 2.14 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.34 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 2.14 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 2.34 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 2.14 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 2.34 OK
B (B ) GROUND FLOOR PLAN - Lift - Width Mt. 1.70 2.14 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 2.34 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 2.14 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.34 OK
TYPICAL - 1, 2 FLOOR PLAN - Lift - Width Mt. 1.70 2.14 OK
TYPICAL - 1, 2 FLOOR PLAN - Lift - Depth Mt. 1.90 2.34 OK
TYPICAL - 1, 2, 3 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.219 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.152 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
STAIRCASE - Flight Width Mt. 0.900 1.219 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.152 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.219 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.152 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
STAIRCASE - Flight Width Mt. 0.900 1.219 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.152 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
STAIRCASE - Flight Width Mt. 0.900 1.219 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.152 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.219 OK
STAIRCASE - Tread Width Mt. - 0.300 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.693 OK
TYPICAL - 1, 2 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.219 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.152 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SUMP TANK Area Sq.Mt. - - 27.34 OK
Width Mt. - - 4.36 OK
Depth Mt. - - 6.28 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 21.16 OK
Width Mt. - - 3.80 OK
Depth Mt. - - 5.57 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.77 OK
Width Mt. - - 0.22 OK
Depth Mt. - - 7.93 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 40.00 OK
Width Mt. - - 5.34 OK
Depth Mt. - - 7.50 OK
Height Mt. - - - OK
Area Sq.Mt. - - 222.68 OK
Width Mt. - - 13.61 OK
Depth Mt. - - 16.36 OK
Height Mt. - - - OK
B (B ) Rain Water Harvesting - No No. 1 - 1 OK
A (A) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For this Authority, No Max. permissible FAR has been provided {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For this Authority, No Max. permissible FAR has been provided {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area above 2000 sq.mt., The minimum width or driveways should not be less than 4.50 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Commercial & Storage buildings having plotarea above 1000 sq.mt., Margin required in Front shall be 9.0 mt., Rear 6.0 mt. and 6.0 mt. shall be provided on both side. {As per Rule No. 38.2.5}
PWork to PWork Margin Reqd Building to Building margin shall be 6 mt. or 1.5 times side setback required for the taller block whichever is high {As per Rule No. 38.1}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(3) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(4) For Non-Residential Building, No Lift is reqd for Building upto G+2 floor {As per Rule No. 49.2.2}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) -
(4) The area of lift well shall not be counted for F.A.R calculation)
(5) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)