No Image Found Detail Scrutiny Report Mineral Area Development Authority
Version Number: 1.0.74
Version Date: 16/10/2020
Report Generated On: 11-11-2024 

[-] Collapse All


[-] Proposal Information (Table 1)
General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDHANBAD
AuthorityMINERAL AREA DEVELOMENT AUTHORITY
Inward_NoMADA/BP/0372/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageKurmidih
Taluka15
Architect Details
Architect NameRAM PRATAP SINGH
License No.MADA/ARC/0024/2019
Architect AddressKAUSHALYA KUTIR SRIRAMKUNJ COLONY NAWADIH HIRAK ROAD
Architect EmailIDar.rampratap@GMAIL.COM
Architect Mobile No9525550001
Plot Details
Plot Use Commercial
Plot SubUse Commercial Bldg
PlotNearbyReligiousStructure NA
Plot/SubPlot NoOLD PLOT NO-1893, NEW PLOT NO-2159
NorthPlot No. - PLOT NO-2158
SouthPlot No. - PLOT NO-2160
EastRoad Width - 9.14
WestPlot No. - PLOT NO-2158

[-]Owner/Applicant details
NameSRI SHYAM PANDEY
AddressKURMIDIH NEAR PANCWATI BARWADDA DHANBAD PANCHWATI
Email IDbhanu.soni20@gmail.com
Mobile No7564902030
  [-] Plot Details (Table 2)
[-] Area From Document (Table 2a)
No. Form Area(Sq. Mt.)
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 566.76
2 Plot area as per Document by Applicant 566.76
3 Physical area measured at site 561.55
4 Area as per Site Visit (Site Visit Report) 561.55
5Area as per Drawing 561.55

Area of Plot Considered : 561.55

Plot area provided in drawing shall not be more than Plot area as per Document. [-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Commercial Bldg
Building StructureMultistoried
Building TypeSingle Detached House
Gross Plot Area 561.55
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 561.55
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 494.65
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 66.90
66.90
Balance Plot Area 494.65

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 280.77
Proposed Coverage Area ( 43.19 % ) 242.52
Total Prop. Coverage Area ( 43.19 % ) 242.52
Balance coverage area ( 6.81 % ) 38.25
FAR CHECK
Perm. FAR Area ( 2.500 ) 1403.88
Total Perm. FAR area 1403.88
Commercial FAR 1336.70
Proposed FAR Area 1359.45
Total Proposed FAR Area 1359.45
Consumed FAR (Factor) 2.42
Balance FAR Area 44.43
BUA CHECK
Total Proposed BuiltUp Area 1603.92


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 9.14 45.72
Proposed Road Width as per Master Plan 9.14 -
Road Widening Width 0 -
Plot size (as per measurement) 561.55 561.55

[-] Road width Details Checks
No Rule Status
1 For Existing Road Width, value as per site visit and value as per drawing should be same. Failed
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)

[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 56.15 66.90 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 66.90 0.00 0.00 - 4.58 - 77.34 No Access Provided OK



[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 15 OK


[-] Building Details (Table 4)

[-] Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure No Of Non-Residential Units Floor Name Floor Use Floor SubUse FAR Name FAR Use FAR SubUse
A (SHYAM) Commercial Commercial Bldg Multistoried 7 BASEMENT FLOOR PLAN Commercial Commercial Bldg - - -
TYPICAL - GROUND, 1& 2 FLOOR PLAN Commercial Commercial Bldg Commercial Commercial Commercial Bldg
TYPICAL - 3, 4, 5& 6 FLOOR PLAN Commercial Commercial Bldg Commercial Commercial Commercial Bldg
TERRACE FLOOR PLAN Commercial Commercial Bldg - - -


[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (SHYAM) 13.71 20.27 20.27 20.27 Failed



[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SHYAM) Sixth Floor 2.75 - 2.90 2.75 - 2.79 2.40 - 2.67 OK
Fifth Floor 2.75 - 2.90 2.75 - 2.79 2.40 - 2.67 OK
Fourth Floor 2.75 - 2.90 2.75 - 2.79 2.40 - 2.67 OK
Third Floor 2.75 - 2.90 2.75 - 2.79 2.40 - 2.67 OK
Second Floor 2.75 - 2.90 2.75 - 2.79 2.40 - 2.67 OK
First Floor 2.75 - 2.90 2.75 - 2.79 2.40 - 2.67 OK
Ground Floor 2.75 - 2.90 2.75 - 2.79 2.40 - 2.67 OK
Basement Floor 2.40 - 2.90 2.40 - 2.79 2.10 - 2.67 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SHYAM) Terrace Floor - - 1.00 - - 1.00 - - 1.00 OK

[-] Basement Floor Check (Table 4a-3)
Building Name Floor Name Height of Basement Floor above GL Area Ventilation Area Status
Reqd Perm Prop Perm Prop Reqd Prop
A (SHYAM) Basement Floor 0.90 1.50 0.00 - 242.52 - 0.00 Failed


[-] Basement Floor Area Check
Building Name Area Status
Perm Prop
A (SHYAM) - 242.52
Total - 242.52 OK

[-] Basement Margin Check
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
  A-1 (SHYAM)   9.14 mt. Wide MainRoad 2.00 6.49 2.00 4.50 2.00 1.51 2.00 3.05 Failed


[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (SHYAM) G + 6 7 - 7 OK


[-] Basement Floor Number Check
Building Name No. of Basement Floor Status
Perm Prop
A (SHYAM) 1 1 OK
  [-] Coverage Check (Table 4b)
Permissible Proposed Status
280.77 242.52 OK
50% 43.19%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (SHYAM) - 242.52
  Total Prop. Coverage Area - 242.52
  Total Coverage Area 280.77 242.52

[-] FAR & Tenement Details
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Parking Commercial Stair
A (SHYAM) 1 1603.92 30.90 213.59 1336.70 22.75 1359.43 1359.43 07
Grand Total : 1 1603.92 30.90 213.59 1336.70 22.75 1359.43 1359.43 07


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (SHYAM)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Basement Floor 242.52 22.75 242.52 22.75
Ground Floor 242.52 242.52 242.52 242.52
First Floor 242.52 242.52 242.52 242.52
Second Floor 242.52 242.52 242.52 242.52
Third Floor 158.46 152.28 158.46 152.28
Fourth Floor 158.46 152.28 158.46 152.28
Fifth Floor 158.46 152.28 158.46 152.28
Sixth Floor 158.46 152.28 158.46 152.28
Terrace Floor 0.00 0.00 0.00 0.00
Total : 1603.92 1359.43 1603.92 1359.43


[-] UnitBUA Table for Building :A (SHYAM)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
TYPICAL - GROUND, 1& 2 FLOOR PLAN OFFICE OFFICE 220.16 220.10 2 3
TYPICAL - 3, 4, 5& 6 FLOOR PLAN OFFICE OFFICE 138.63 138.53 3 4
Total: - - 1214.97 1214.40 18 7


[-] Building :A (SHYAM)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Parking Commercial Stair
Basement Floor 242.52 6.18 213.59 0.00 22.75 22.75 22.75 00
Ground Floor 242.52 0.00 0.00 242.52 0.00 242.52 242.52 01
First Floor 242.52 0.00 0.00 242.52 0.00 242.52 242.52 01
Second Floor 242.52 0.00 0.00 242.52 0.00 242.52 242.52 01
Third Floor 158.46 6.18 0.00 152.28 0.00 152.28 152.28 01
Fourth Floor 158.46 6.18 0.00 152.28 0.00 152.28 152.28 01
Fifth Floor 158.46 6.18 0.00 152.28 0.00 152.28 152.28 01
Sixth Floor 158.46 6.18 0.00 152.28 0.00 152.28 152.28 01
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 1603.92 30.90 213.59 1336.70 22.75 1359.43 1359.43 07
Total Number of Same Buildings : 1
Total : 1603.92 30.90 213.59 1336.70 22.75 1359.43 1359.43 07

[-] Table 4c-2
  FAR Area Perm. Prop. Status
Building FAR Area : 1359.45
Existing FAR Area : 0.00
1403.88 1359.45 OK



[-] Mandatory setbacks Checks (Table 5)
[-] Plot Mandatory setbacks (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (SHYAM) 9.14 mt. Wide MainRoad 7.50 6.49 4.50 4.50 4.50 1.51 4.50 3.05 Failed




[-] Inner Building Details (Table 6)

[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (SHYAM) 20.27 2 2 - 0 12 12 OK

[-] Lift Check Table

[-] For Building :A (SHYAM)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
BASEMENT FLOOR PLAN Lift 1.70 1.70 1.90 1.82 Failed
Lift 1.70 1.70 1.90 1.82 Failed
TYPICAL - GROUND, 1& 2 FLOOR PLAN Lift 1.70 1.70 1.90 1.82 Failed
Lift 1.70 1.70 1.90 1.82 Failed
TYPICAL - 3, 4, 5& 6 FLOOR PLAN Lift 1.70 1.70 1.90 1.82 Failed
Lift 1.70 1.70 1.90 1.82 Failed
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.70 1.90 1.82 Failed
Lift Machine Room 1.70 1.70 1.90 1.82 Failed


[-] Parking Details (Table 7)

[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (SHYAM) Commercial Commercial Bldg > 0 200 1158.90 1 4 - - - - - - -
> 0 200 1158.90 - - - - - - 1 13 -
Total : - - - - 4 11 - 0 4 - 13 30

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 11 132.50 OK
Total Car 4 50.00 11 132.50 OK
Visitor's Car Parking - - 4 50.00 OK
Total Visitor Parking - - 4 50.00 OK
TwoWheeler - - 30 60.02 OK
Total TwoWheeler 13 26.00 30 60.02 OK
Other Parking - - - 45.08 OK
Total 76.00 347.62 OK

Individual Parking Checks (Table 7c)

Building Level Car
NameAreaDimStatus
CP 7.50 2.5 x 3.00 Failed


[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
PLOT - DRIVEWAY 3.60 - 5.00 OK
A (SHYAM) BASEMENT FLOOR PLAN D1 3.60 - 4.24 OK
D2 3.60 - 3.53 Failed


[-] Exemption Details (Table 8)


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (SHYAM)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
BASEMENT FLOOR PLAN STAIRCASE 0.900 1.829 0.250 0.305 0.200 0.000 - 0 - - 0.000 OK
TYPICAL - GROUND, 1& 2 FLOOR PLAN STAIRCASE 0.900 1.829 0.250 0.305 0.200 0.132 - 11 - - 0.000 OK
TYPICAL - 3, 4, 5& 6 FLOOR PLAN STAIRCASE 0.900 1.829 0.250 0.305 0.200 0.132 - 11 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.829 - 0.305 - 0.000 - 0 - - 2.591 OK


[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
15.25 mt. long 2.42 mt. High 6.10 mt. Wide Natural Slope 3.30 6.08 1.00 2.42 1.00 : 10.00 1.00 : 20.00 01 : 07 Failed


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (SHYAM) BASEMENT FLOOR PLAN 1 1 OK

In A (SHYAM) Bldg in BASEMENT FLOOR PLAN , 15.25 mt. long 2.42 mt. High 6.10 mt. Wide Natural Slope must have mini. 4.50 mt. Distance From the Plot.

[-] Arch Projection Checks (Table 8c)
[-] For Building :A (SHYAM)
Floor Name Arch Proj Name Width Depth Area Status
Perm Prop Perm Prop Perm Prop
TYPICAL - GROUND, 1& 2 FLOOR PLAN CHHAJJA 0.75 0.61 - 2.03 - 1.24 OK
CHHAJJA 0.75 0.61 - 2.03 - 1.24 OK
CHHAJJA 0.75 0.61 - 2.03 - 1.24 OK
CHHAJJA 0.75 0.61 - 2.03 - 1.24 OK
CHHAJJA 0.75 0.61 - 2.78 - 1.69 OK
CHHAJJA 0.75 0.61 - 2.14 - 1.30 OK
CHHAJJA 0.75 0.61 - 2.14 - 1.30 OK
CHHAJJA 0.75 0.61 - 2.14 - 1.30 OK
TYPICAL - 3, 4, 5& 6 FLOOR PLAN CHHAJJA 0.75 0.61 - 2.03 - 1.24 OK
CHHAJJA 0.75 0.61 - 2.03 - 1.24 OK
CHHAJJA 0.75 0.61 - 2.03 - 1.24 OK
CHHAJJA 0.75 0.61 - 2.03 - 1.24 OK
CHHAJJA 0.75 0.61 - 2.03 - 1.24 OK
CHHAJJA 0.75 0.61 - 2.14 - 1.30 OK
CHHAJJA 0.75 0.61 - 2.14 - 1.30 OK
CHHAJJA 0.75 0.61 - 2.03 - 1.24 OK
CHHAJJA 0.75 0.61 - 2.14 - 1.30 OK

[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 7.26 - - 1.91 - - 3.80 - - 0.00 OK
RAIN WATER HARVESTING - - 2.70 - - 0.99 - - 2.73 - - 0.00 OK
ENT.GATE - - 1.84 - - 0.30 - - 6.08 - - 0.00 OK
SOLAR HEATING SYSTEM - - 9.36 - - 1.75 - - 5.35 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (SHYAM) Rain Water Harvesting 1 - 1 OK
Toilet 1 - 0 Failed
Entrance Gate 1 - 1 OK

[-] Floor Details (Table 9)



[-] Building:A (SHYAM)


[-] Floor:BASEMENT FLOOR PLAN



No Room Found.


[-] Floor:TYPICAL - GROUND, 1& 2 FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:TYPICAL - 3, 4, 5& 6 FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.



[-] Summary (Table 4)
Name Perm./Reqd. Proposed Status
  Plot Area - 561.55 OK
  Plot Width - 16.15 OK
  Plot Depth - 34.76 OK
  Access Width 6.10 45.72 OK
  Plot Frontage - 3.87 OK
  Coverage Area 280.77 242.52 OK
  FAR Area
Bldg. FAR Area : 1359.45
Sanctioned FAR Area :0.00
1403.88 1359.45 OK




NOTE : This report is generated based on the inputs or drawing provided by the Applicant. The approval is subjected to further verification by concerned scrutiny officer.
Accuracy of Scrutiny Report and Drawing is subject to accuracy of end-user provided data, 3rd party software/hardware/services, etc. We are not liable for any damages which may arise from use, or inability to use the Application.

[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation and MADA Area, Max. 2.5 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Dhanbad Municipal Corporation and MADA Area, Max. 2.5 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Multistoried Building, having Building Height 19.25-23.10 mt.,Margin required in Front shall be 7.5 mt., Rear 4.5 mt. and 4.5 mt. shall be provided on both side. {As per Rule No. 37 Table 14}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 2 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Parking -
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height The minimum height of the ceiling of upper basement shall be 0.90m. and the maximum, 1.5 m. above the average surrounding ground level {As per Rule No. 48},
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp For parking spaces in basements and upper storey of parking floors,if car parking is less then 40, one ramp of minimum of 3.30m width if it is strait and 4.5m width if it is curved at any point and with minimum slope gradient of 1:7 for depth up to 1.8m and 1:10 for more than 1.8m depth shall be provided. For height more than 2.4m,slope shall not exceed 1:20. {As per Rule No. 41.8 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017} ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
For parking spaces in basements and upper storey of parking floors,if car parking is less then 40, one ramp of minimum of 3.30m width if it is strait and 4.5m width if it is curved at any point and with minimum slope gradient of 1:7 for depth up to 1.8m and 1:10 for more than 1.8m depth shall be provided. For height more than 2.4m,slope shall not exceed 1:20. {As per Rule No. 41.8 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017} ;
Arch Projection (1) No need to check
(2) Chhajja,Cornice or Weather shed of upto 0.75m width shall be permitted. {As per Rule No. 46.1}
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) Provision of toilets for visitors and separate toilets for guards and drivers shall be provided for Multistoried for Commercial and multidwelling units including Apartments Toilet
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)