Detail Scrutiny Report

Kapali Nagar Panchayat

Version Number: 1.0.68  
Version Date: 16/10/2020 
Report Generated On: 29-12-2023 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSERAIKELA
AuthorityKAPALI NAGAR PANCHAYAT
Inward_NoKANPC/BP/W20/0018/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageVillage 1
Taluka37
Architect Details
Architect NameNIKHIL SHUKLA
License No.KANPC/ARC/0001/2020
Architect AddressHOUSE NO- 125, CHANAKYAPURI COLONY, OLD PURULIA ROAD, NEAR JESU MANGO, JAMSHEDPUR
Architect EmailIDnikhil.archi@gmail.com
Architect Mobile No9234459150
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No230
North -
South -
EastRoad Width - 7.60 MTR WIDE MAIN ROAD Access Road
West -
Owner's Details
NameMAZHAR ALI
AddressPLOT NO-242, MAHTO PARA ROAD, HILL VIEW AREA, JUGSALAI, JAMSHEDPUR
Email IDmazhar153.ali@gmail.com
Mobile No9234511228
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 792.36
2 Plot area as per Document by Applicant 459.94
3 Physical area measured at site 459.94
4 Area as per Site Visit (Site Visit Report) 459.94
5Area as per Drawing 458.94

Area of Plot Considered : 458.94

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 458.94
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 458.94
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 375.71
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 83.22
83.22
Balance Plot Area 375.71

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 275.36
Proposed Coverage Area ( 45.76 % ) 210.00
Total Prop. Coverage Area ( 45.76 % ) 210.00
Balance coverage area ( 14.24 % ) 65.36
FAR CHECK
Perm. FAR Area ( 2.500 ) 1147.35
Total Perm. FAR area 1147.35
Residential FAR 897.98
Proposed FAR Area 916.68
Total Proposed FAR Area 916.68
Consumed FAR (Factor) 2.00
Balance FAR Area 230.67
BUA CHECK
Total Proposed BuiltUp Area 1119.71


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 7.6 7.60
Proposed Road Width as per Master Plan 7.6 -
Road Widening Width 0 -
Plot size (as per measurement) 459.94 458.94
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 22.95 83.22 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 83.22 0.00 0.00 - 4.08 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 18 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (MAZHAR ALI) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (MAZHAR ALI) 14.58 14.25 14.25 14.25 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (MAZHAR ALI) Fourth Floor 2.75 - 2.85 2.75 - 2.76 2.40 - 2.66 OK
Third Floor 2.75 - 2.85 2.75 - 2.76 2.40 - 2.66 OK
Second Floor 2.75 - 2.85 2.75 - 2.76 2.40 - 2.66 OK
First Floor 2.75 - 2.85 2.75 - 2.76 2.40 - 2.66 OK
Ground Floor 2.75 - 2.85 2.75 - 2.76 2.40 - 2.66 OK
Plinth 0.45 - 0.50 - - 0.50 - - 0.50 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (MAZHAR ALI) Terrace Floor - - 1.07 - - 1.07 - - 1.07 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (MAZHAR ALI) G + 5 5 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
275.36 210.00 OK
60% 45.76%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (MAZHAR ALI) - 210.00
  Total Prop. Coverage Area - 210.00
  Total Coverage Area 275.36 210.00

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Balcony Accessory Use Parking Resi. Stair
A (MAZHAR ALI) 1 1119.71 15.24 16.17 19.80 151.83 897.98 14.89 916.67 916.67 01
Grand Total : 1 1119.71 15.24 16.17 19.80 151.83 897.98 14.89 916.67 916.67 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (MAZHAR ALI)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 210.00 58.17 210.00 58.17
First Floor 219.35 210.59 219.35 210.59
Second Floor 230.12 215.97 230.12 215.97
Third Floor 230.12 215.97 230.12 215.97
Fourth Floor 230.12 215.97 230.12 215.97
Terrace Floor 0.00 0.00 0.00 0.00
Total : 1119.71 916.67 1119.71 916.67


[-] UnitBUA Table for Building :A (MAZHAR ALI)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT A FLAT 760.49 759.78 4 1
FIRST FLOOR PLAN SPLIT A FLAT 0.00 0.00 14 0
SECOND FLOOR PLAN SPLIT A FLAT 0.00 0.00 14 0
THIRD FLOOR PLAN SPLIT A FLAT 0.00 0.00 14 0
FOURTH FLOOR PLAN SPLIT A FLAT 0.00 0.00 14 0
Total: - - 760.49 759.78 60 1


[-] Building :A (MAZHAR ALI)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Balcony Accessory Use Parking Resi. Stair
Ground Floor 210.00 0.00 0.00 0.00 151.83 39.48 14.89 58.17 58.17 01
First Floor 219.35 3.81 0.00 4.95 0.00 210.59 0.00 210.59 210.59 00
Second Floor 230.12 3.81 5.39 4.95 0.00 215.97 0.00 215.97 215.97 00
Third Floor 230.12 3.81 5.39 4.95 0.00 215.97 0.00 215.97 215.97 00
Fourth Floor 230.12 3.81 5.39 4.95 0.00 215.97 0.00 215.97 215.97 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 1119.71 15.24 16.17 19.80 151.83 897.98 14.89 916.67 916.67 01
Total Number of Same Buildings : 1
Total : 1119.71 15.24 16.17 19.80 151.83 897.98 14.89 916.67 916.67 01
[-] Table 4c-2

  FAR Area
Building FAR Area:916.68
Existing FAR Area :0.00
Perm.
1147.35
Prop.
916.68
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (MAZHAR ALI) 7.60 MTR WIDE MAINROAD 3.00 3.18 2.00 3.05 2.50 2.70 2.50 2.61 OK






[-] Inner Building Details (Table 6)
   
   
[-] Balcony Details (Table 6c)

[-] For Building:A (MAZHAR ALI)
Floor Name Balcony Name Width Status
Perm Prop
SECOND FLOOR PLAN BALCONY 1.20 1.09 OK
BALCONY - 1.09 OK
THIRD FLOOR PLAN BALCONY 1.20 1.09 OK
BALCONY - 1.09 OK
FOURTH FLOOR PLAN BALCONY 1.20 1.09 OK
BALCONY - 1.09 OK



For PWork At Layout : 

No Balcony Found.

   
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (MAZHAR ALI) 14.25 - 1 - 0 - 6 OK

[-] Lift Check Table

[-] For Building :A (MAZHAR ALI)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
GROUND FLOOR PLAN Lift 1.70 1.84 1.90 2.07 OK
FIRST FLOOR PLAN Lift 1.70 1.84 1.90 2.07 OK
SECOND FLOOR PLAN Lift 1.70 1.84 1.90 2.07 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.84 1.90 2.07 OK
THIRD FLOOR PLAN Lift 1.70 1.84 1.90 2.07 OK
FOURTH FLOOR PLAN Lift 1.70 1.84 1.90 2.07 OK

   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (MAZHAR ALI)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (MAZHAR ALI)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 1.227 0.250 0.281 0.200 0.150 - 10 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.900 1.227 0.250 0.281 0.200 0.150 - 10 - - 0.000 OK
SECOND FLOOR PLAN STAIRCASE 0.900 1.227 0.250 0.281 0.200 0.150 - 10 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.227 - 0.281 - 0.000 - 0 - - 2.500 OK
THIRD FLOOR PLAN STAIRCASE 0.900 1.227 0.250 0.281 0.200 0.150 - 10 - - 0.000 OK
FOURTH FLOOR PLAN STAIRCASE 0.900 1.227 0.250 0.281 0.200 0.150 - 10 - - 0.000 OK

   
   
   

[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
0.75 mt. long 0.15 mt. High 2.68 mt. Wide Natural Slope - 0.75 - 0.15 - - - OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (MAZHAR ALI) GROUND FLOOR PLAN - 1 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SewageTreatmentPlant - - 0.96 - - 0.98 - - 0.98 - - 0.00 OK
RAIN WATERHARVESTING - - 1.55 - - 1.16 - - 1.34 - - 0.00 OK
ENT.GATE - - 1.24 - - 0.48 - - 2.60 - - 0.00 OK
Entrance Lobby - 12.00 4.95 - - 2.07 - - 2.39 - - 0.00 OK
Entrance Lobby - 12.00 4.95 - - 2.07 - - 2.39 - - 0.00 OK
Entrance Lobby - 12.00 4.95 - - 2.07 - - 2.39 - - 0.00 OK
Entrance Lobby - 12.00 4.95 - - 2.07 - - 2.39 - - 0.00 OK
SOLARHEATING SYSTEM - - 1.52 - - 1.16 - - 1.31 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (MAZHAR ALI) Rain Water Harvesting 1 - 1 OK
Solar Water Heating System 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (MAZHAR ALI)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:SECOND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:THIRD FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FOURTH FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 458.94 OK
  Plot Width - 24.53 OK
  Plot Depth - 18.71 OK
  Access Width 6.10 7.60 OK
  Plot Frontage - 24.53 OK
  Coverage Area 275.36 210.00 OK
  FAR Area
Bldg. FAR Area : 916.68
Sanctioned FAR Area :0.00
1147.35 916.68 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) 0.0
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) 0.0
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 15-21 mt. and Plot width 21-27 mt., Margin required in Front shall be 3.0 mt., Rear 2.0 mt. and 2.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9 and updated as per 4th Amendment dated 2nd Jan, 2019}
Building Level
Building Height For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony Projected balcony may be allowed with a widt of 1.2 mt. where the setback is more than 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. -
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SewageTreatmentPlant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATERHARVESTING
(5) No need to check distance from Building ENT.GATE
(6) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(7) No need to check distance from Building Entrance Lobby
(8) -
(9) No need to check distance from Building SOLARHEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)
Kitchen3.64x3.32 Area for Kitchen when store room is provided shall be Mini. 4.5 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Servant Room3.04x4.00 No Rule Defined
Toilet1.53x1.93 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet1.53x1.96 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}